Language: LADDER (contact diagram)
Program: Siemens LOGO! Soft Comfort v8.x
Digital Inputs: 6 (inductive sensors for vehicle entry and exit, optical barrier sensors, control push buttons, and adjustment and reset inputs via LOGO! TD keypad)
Digital Outputs: 4 (access barrier actuation, “Space Available” and “Full” light signaling, and system visual alert devices)
Safety: The system incorporates detection via inductive and optical sensors, access control based on a configurable maximum capacity, automatic blocking of entry when the parking area is full, and alert and signaling functions that ensure safe and orderly operation.
Included Documentation: Technical report, design logic, electrical drawings, and program.
(edit with the Customer Reassurance module)
(edit with the Customer Reassurance module)
(edit with the Customer Reassurance module)